Back to listLingSante-Pulse: One Model for Understanding Diverse Physiological Waveforms, from 30-Second Windows to Six-Year Disease Risk inclusionai November 20, 2026 10 min read

We propose a physiological signal foundation model pretrained on more than 150,000 hours of physiological time-series data across diverse scenarios— LingSante-PulseThe model uses a universal encoder to process various types of physiological sensor data, enabling flexible transfer and reuse across signal types and sensor combinations. Based on a single night of sleep-monitoring data, it can predict the six-year incidence risk of 150 disease phenotypes. The number of predictable disease phenotypes meeting statistical reliability standards is approximately 42% higher than that of the current leading model. In evaluations spanning 38 single-sensor, non-sleep prediction tasks across electroencephalography (EEG), electrocardiography (ECG), photoplethysmography (PPG), and electromyography (EMG), as well as multimodal sleep staging and single-channel sleep apnea detection, LingSante-Pulse comprehensively outperforms existing sensor-specific domain models and multimodal physiological signal foundation models.

LingSante-Pulse 主要评测结果

Top row: LingSante-Pulse ranks first on average across multiple single-sensor and multimodal tasks

Middle row: LingSante-Pulse outperforms other external models on representative datasets and tasks

Bottom row: LingSante-Pulse ranks first in both long-term disease-risk estimation metrics and the number of diseases covered by its predictions

Why Physiological Signals Need a Unified Model

The heart’s electrical activity, blood flow through peripheral vessels, brain oscillations, and the rise and fall of breathing collectively reflect the body’s physiological state. Physiological signals commonly used in clinical practice include:

  • **Electroencephalography (EEG):** Scalp electrodes record synchronized changes in the electrical potentials of neuronal populations in the cerebral cortex, reflecting the brain’s functional state and rhythmic activity.
  • **Electrocardiography (ECG):** Surface electrodes record potential differences produced by cardiac depolarization and repolarization, enabling analysis of heart rate, rhythm, conduction, myocardial ischemia, and other aspects of cardiac electrical activity.
  • **Photoplethysmography (PPG):** Optical technology measures pulsatile changes in blood volume within peripheral vessels, providing noninvasive measurements of heart rate, respiratory modulation, and SpO₂. It is a primary signal used by smartwatches and other wearable devices.
  • **Electrooculography (EOG):** Electrodes placed around the eyes record potential changes caused by eye rotation, enabling detection of the direction and speed of eye movements.
  • **Electromyography (EMG):** Electrodes record motor-unit action potentials during muscle contraction, enabling assessment of muscle activity, tone, and neuromuscular function.
  • **Respiratory signals (RESP):** Chest or abdominal belts, nasal airflow thermistors, pressure sensors, and other devices record respiratory movement, reflecting breathing rate, amplitude, and effort and enabling the detection of respiratory events such as apnea and hypopnea.

LingSante-Pulse 灵活传感器输入与下游应用

LingSante-Pulse supports flexible inputs and a wide range of downstream applications

However, real-world medical and health-monitoring settings are oftenfragmented: polysomnography (PSG) simultaneously records EEG, EOG, EMG, ECG, and respiratory signals; cardiology examinations focus on 12-lead ECG; and everyday wearable devices typically provide only PPG, single-lead ECG, and similar signals. These signals observe the sameinterconnectedhuman physiological system from different perspectives, yet their modality coverage overlaps only partially.

Existing physiological-signal research faces a dilemma:Unimodal specialized modelsare constrained by the scale of a single data source, overlook coupling relationships among signals from different sensors, and are difficult to reuse across settings;multimodal modelstypically focus on specific scenarios, such as sleep models with fixed channel combinations. Although they emphasize the complementary nature of multiple modalities, their representation capabilities deteriorate sharply when some modalities are missing or only unimodal data is available. We therefore pose a central question:Can a universal shared encoder be learned from these partially overlapping, heterogeneous recordings—one that can integrate the global picture when multimodal signals are available while outperforming domain-specific models when only a single type of signal is provided??

LingSante-Pulse provides an affirmative answer. Whether the task is classifying motor imagery from EEG, classifying arrhythmias from 12-lead ECG, estimating heart rate from wrist PPG under motion interference, reconstructing finger-motion trajectories from EMG, performing full-night sleep staging, or screening for apnea using a single lead, the same frozen LingSante-Pulse encoder can be reused without retraining the underlying encoder for every input configuration.

Model Overview

LingSante-Pulse 预训练架构概览

Model architecture: collaborative pretraining with three types of self-supervised objectives

Waveforms from the input physiological channels are uniformly sampled at 128 Hz and divided into non-overlapping 30-second segments. To process signals from different modalities with the same encoder, we convert natural-language text describing the “modality + lead” into conditioning vectors using a frozen text encoder and feed them into the model together with the signals. Each physiological channel passes through the encoder independently, allowing the model to naturally support any number and combination of sensor inputs.

To enable the model to learn bothcross-modal commonalitiesandeach signal’s own waveform, spectral, and rhythmic information, LingSante-Pulse pretraining combines three complementary self-supervised objectives:

  1. Pairwise cross-modal alignment: Signal pairs collected synchronously within the same time window are brought closer together in the projection space, while distribution regularization prevents representation collapse;

  2. Structured random-feature prediction: A continually refreshed structured random teacher network generates prediction tasks, while cross-sample linear prediction ensures the effectiveness of the representations;

  3. Masked waveform reconstruction: Fifty percent of valid waveform segments are masked and reconstructed with a lightweight decoder, forcing the model to learn fine-grained local waveform morphology.

During inference, the teacher, linear head, alignment projector, and decoder are discarded. Only the frozen shared encoder is retained; each channel is encoded independently and then passed to a lightweight downstream prediction head.

Learning Shared Physiological Structure from Incomplete Records

Real-world observational data often contain only partially paired physiological signals. For example, Dataset A records EEG and ECG together, Dataset B records ECG and respiration together, while Dataset C contains only multi-lead ECG.

LingSante-Pulse treats the entire pretraining corpus as asparse network graph: Each type of physiological signal is a node, and pairs of synchronously collected signals form edges. Signals such as ECG, which occur frequently across settings, serve ashubs, connecting signals that would otherwise remain isolated from one another.

The model independently encodes each physical channel and performs pairwise alignment of representations from different signals belonging to the same individual and time window. This design does not require every record to contain a complete set of modalities, while also exhibiting a remarkable **“transitive transfer” effect**: even if two signals have never been paired directly, such as EEG and respiration, they can still benefit each other as long as each is connected separately to a hub such as ECG.

We validated this transfer effect in a controlled “EEG-ECG-respiration” experiment: during training, only EEG-ECG and ECG-respiration pairs were provided, while at test time only respiratory signals were input for the sleep-staging task (the human-expert gold standard primarily uses EEG to determine sleep stages). The results showed that, compared with control groups that either excluded EEG or shuffled the EEG pairings, introducing correctly aligned auxiliary EEG-ECG data significantly improved the accuracy of single-channel respiration-based sleep staging (Macro-F1) by 4.21 percentage points (0.399->0.439). This demonstrates that LingSante-Pulse successfully transfers the benefits of jointly observed multimodal data across multiple datasets to downstream tasks involving an isolated single sensor.

Preserving the intrinsic structure of signals through continuously refreshed random prediction tasks

Cross-modal alignment excels at capturing broad states but can easily overlook morphological details unique to an individual signal, such as the morphology of ECG QRS complexes and transient EEG sleep spindles. This channel-specific information is also valuable and needs to be preserved in the representations.

We proposestructured random-feature predictionDuring each training update, the system randomly initializes a new teacher network to characterize the input signal’s intrinsic structural features, guiding the student to predict the teacher’s output from its own representation through a simple linear mapping. Because the teacher network is refreshed at every step, the encoder continually faces different signal-measurement tasks. It cannot learn shortcuts toward a single fixed target and is instead forced to preserve the signal’s intrinsic structural features in the representation space.

Waveform reconstruction requires the model to recover masked waveform segments, thereby preserving local signal details. Ablation experiments show that the two methods areperfectly complementary—the random teacher excels at predicting amplitude, event locations, and spectral properties, while reconstruction is better at predicting local measures such as inter-pulse intervals.

Single-sensor prediction tasks: outperforming domain-specific models

We evaluated the generalizability of the model’s representations on 38 non-sleep tasks spanning four domains: PPG, ECG, EEG, and EMG. The tasks ranged from wrist-based PPG heart-rate estimation and 12-lead arrhythmia classification to 64-channel EEG motor imagery and continuous movement-trajectory decoding from 2,000 Hz EMG. The baselines included the latest domain-specific foundation models in each field. During evaluation, the encoders of all models were frozen, and only lightweight prediction heads corresponding to each task were trained, with the focus on testing the reusability of the pretrained representations themselves.

LingSante-Pulse achievedthe best average dataset ranking in all four domains(PPG 2.32, ECG 3.08, EEG 3.00, and EMG 1.33)—with a single general-purpose model outperforming specialized experts across all four domains.

  • **PPG:** On the DaLiA dataset’s wrist-based PPG heart-rate estimation task under intense motion interference, its error (MAE) was 25.1% lower than that of the strongest domain-specific model. On the WESAD dataset, its accuracy in classifying emotional and stress states (Macro-F1) exceeded the runner-up by 9.83 percentage points.
  • **ECG:** By simply concatenating features independently encoded from the individual leads, it outperformed a specialized 12-lead ECG model in 12-lead arrhythmia-classification accuracy (Macro-F1).
  • **EEG:** Its accuracy (Macro-F1) surpassed that of the strongest domain-specific model on both the 64-channel motor-imagery task and the three-channel mental-arithmetic task.
  • **EMG:** In the finger-movement trajectory-decoding task, although LingSante-Pulse was pretrained at 128 Hz, it still achieved a lower prediction error (MAE) than the domain-specific model when applied directly to 2,000 Hz EMG signals.

四组单模态任务中各模型的平均排名

Average model rankings across four groups of unimodal prediction tasks

单模态回归与分类任务代表性结果

Top row: errors on unimodal regression tasks (MAE; lower is better)

Bottom row: accuracy on unimodal classification tasks (Macro-F1; higher is better)

Sleep monitoring: from multimodal whole-night sleep staging to single-lead screening

Sleep staging

We tested automated sleep staging on the public polysomnography (PSG) datasets HMC and Sleep-EDF20, namelydetermining whether each 30-second interval throughout the night corresponds to wakefulness (Wake), rapid eye movement sleep (REM), sleep onset (N1), light sleep (N2), or deep sleep (N3)。

  • Strongest multimodal prediction capabilityWith all channels as input and whole-night contextual information incorporated, LingSante-Pulse achieved a Macro-F1 of 0.7859 for whole-night sleep staging, outperforming all other external multimodal sleep models.
  • **Unimodal input outperforms external multimodal input:** On the HMC dataset, using only four EEG channels, LingSante-Pulse surpassed external models that used the full set of EEG, EMG, EOG, ECG, and respiratory inputs, indicating that LingSante-Pulse extracts features from unimodal signals extremely thoroughly.

多模态与单模态睡眠分期效果

Sleep-staging performance; higher Macro-F1 indicates better performance

a. All PSG channels as input; b. EEG only; c. EOG only; d. EMG only

Sleep-apnea screening

Sleep apnea is one of the most closely watched health risks in sleep medicine. We tested LingSante-Pulse on the Apnea-ECG benchmark datasetusing only a single-lead ECG to determine, minute by minute, whether the patient experienced apnea during that minute。

The results showed that LingSante-Pulse achieved a screening accuracy (AUROC) of 0.918, more than ten percentage points higher than that of a specialized ECG foundation model.

单导联心电呼吸暂停筛查效果

Single-lead ECG sleep-apnea screening accuracy (AUROC; higher is better)

Long-term disease-risk estimation

The value of physiological representations also lies in their reusability across different prediction horizons. We investigated whether whole-night physiological recordings could support long-term risk analysis. The model takes nine channels of sleep signals as input and aims to predicthundreds of disease phenotypes spanning all major clinical categoriestheirfirst new diagnosis。

After age and sex features were introduced, LingSante-Pulse achieved a six-year prediction accuracy (IPCW AUROC) of 0.745, 3.06 percentage points higher than the strongest external model. It produced **“strong discrimination” (both IPCW AUROC and Harrell’s C-index above 0.75) for 150 diseases**, 31 more than the strongest external model (+25.8%). After removing age and sex inputs, LingSante-Pulse still achieved a six-year prediction accuracy of 0.741, demonstrating that most of its predictive capability comes from the physiological waveforms themselves rather than demographic statistics.

整夜睡眠信号预测长期疾病风险

a: Harrell’s C-index, with higher values indicating better performance; b: three-year IPCW AUROC, with higher values indicating better performance;

c: six-year IPCW AUROC, with higher values indicating better performance; d: number of diseases with “strong discrimination,” with higher values indicating better performance

长期疾病风险覆盖广度

Number of diseases with “strong discrimination” for each model across major clinical categories

To verify whether the model can help identify genuinely high-risk populations, we divided participants into low-, medium-, and high-risk groups based on model scores. Taking “developmental delay” as an example, the probabilities of receiving a diagnosis within six years were 8.8%, 20.7%, and 63.4% for the model-defined low-, medium-, and high-risk groups, respectively—a difference of more than sevenfold. By contrast, when predictions were based only on age and sex, the low- and medium-risk groups were almost indistinguishable (22.3% vs. 21.6%). This indicates that the model’sassessment of future disease risk is strongly consistent with actual outcomes: people classified by the model as high risk are indeed significantly more likely to receive a future diagnosis than those classified as low risk.

We also found an interesting result: using only two minimal channels—a single-lead ECG and a chest-belt respiratory signal—LingSante-Pulse already achieves “strong discrimination” for 118 diseases, nearly matching the 119 achieved by the strongest external model using all channels. This points to the model’s enormous potential for futureapplication in home and wearable-device settings—with only a limited number of easy-to-collect sensor signals, it can provide long-term disease risk screening comparable to that of a professional sleep laboratory.

Toward a Reusable Physiological Foundation Model

LingSante-Pulse presents a new way to connect heterogeneous physiological recordings: it uses synchronized data acquisition to learn the intrinsic relationships among different signals, while continually refreshed random teachers and masked reconstruction preserve the fine-grained structure of each signal. The resulting general-purpose representations can be seamlessly reused across different sensor combinations and tasks spanning different timescales.

We hope this approach will turn physiological recordings scattered across diverse settings into shared research resources, helping future AI health models better adapt to the rich variety of real-world data.

References

Model Release · HealthcarePrevious: LingSante-3.1-air-VL Officially Released: A Native Multimodal Model for Real-World Medical TasksNext: Ling-3.1-flash Officially Open-Sourced: Turning Real Business Needs into Usable Results Faster